﻿Control
Settings
No authority
Lan
User
Time
E-Mail
I/O
Power Measure
Switching
Wake On LAN
Timer
Keepalive
Backup
Logbook
Help
Ver.:
Power Events
Power Measurement
Logout: close browser.
Settings/IO
IO Input
IO In-/Output
Relays
Sockets
blocked
(Timer & Keepalive is on)
(Timer is on)
(Keepalive is on)
Output
inverted
Input - no switching



Network Settings
Hostname
 no special characters or spaces
Automatic IP setting
(for a static IP switch DHCP off)
TCP/IP Settings
These parameters are assigned by DHCP.
Mask:
First DNS:
Secound DNS:
The MAC can not be changed.
Allow UDP communication
Send
(port number)
Receive
After saving the device restarts!<br>After IP - change we recommend to turn device off and on.
Do you want to reboot?
Factory Settings
1. All names are reset
2. All relays are allowed
The state of the relay is maintained.
Do you want to reset to factory parameters?
Save
Save and Restart?
Restart
<br><br>Error: Defective data received. <u><a href="#" onclick="window.location.reload()">Call again.</a></u><br><br>At repeated problems: <u><a href="html_upl.htm" target="if1">Upload HTML</a></u>.<br><br>
made










User Rights
Username and password are limited to 12 characters. Options without permission are in menu not displayed. This setting also applies to the UDP control. Incorrect login blocks this for 3 seconds.
User name
Password
Permission
 without authentication / login
 All options allowed.
Relays/sockets can be locked for users who are shown as inactive (how locked in Setting/Switching).
Control
Lan
User
Time
E-Mail
IO
Switching
WOL
Power Meter
Timer
Keep alive
Backup
Logbook
Relays:
After changing the language<br>Browser will be refreshed.
Upload HTML
Firmware Update
Sensor


Time Setting
with the Internet time server (SNTP port 123):
The time is synchronized automatically (every 60 min.) with the Internet Time Server (SNTP).
Port 123 should not be blocked.
After the restart/power-failure the clock is synchronized immediately.
 Internal clock:
SNTP test
Permit
SNTP Server:  
DST correction
Sunrise and sunset
To calculate the sunrise and sunset: specify time zone according to UTC, latitude and longitude.
Latitude in the format: ± 90.0°. South latitude with minus in the front. Longitude in the format: ± 180.0°.
West longitude with minus in front. In the summer time 1 hour will be added.
Time zone
Geo. location
LAT±90,0° LONG±180,0°
Calculated
sunrise:
sunset:
+north<br>-south
+east<br>-west
Correction
Timer-time
 latitude
 longitude
Set the clock
synchronize with browser time:
If Internet access is not possible, the internal clock must be synchronized with system (computer time).
The automatic synchronization in this mode is not possible.
It is important (after a power failure) to make manually synchronization because the timers can not work without clock.
 System time:
It's summertime
It is winter time
Clock has been set.
Error: The clock could not be found <br> Please check the NTP server settings.
 min. 



 E-Mail Notification
Message has been sent.
 ERROR: Message could not be sent <br> Please check your e-mail settings.<br>SMTP Error =
failure can be reported by e-mail.
Max. 10 messages will be collected or sent after 10 sec.
The emails are numbered bottom right.
SMTP port 465 (SSL), unfortunately, can not be supported.
look here for solutions.
Send at:
Relay/Socket switch
Login
Change the IO
Clock synchronization
Change of settings
Power Events
SMTP settings
SMTP Server:
Hostname or IP.
&nbsp;Port:
at:
cc:
If email not arrive, a reset is recommended.
All text fields max. 48 characters<br>message max. 64 characters.
from:
Subject:
Message:
Reset
Login SMTP Server:
User:
Password:
'Test' stores the settings and sends a test - mail. The result is displayed at the top.
 Test 
Do you want to reset?


Settings I/O
IO switch on
No.
Name
Output
Input
Invers
Control
Switch relay(s) thru I/O:
 IO
 Relays
 Switch IO Pull Up Resistor
 IO generator switch on


Switching
Name <span style="color:#A0A0A4">/Position/Function </span>
 After changing refresh page.
Lock
Impuls
at the start:
on when Temp.
since reboot
sec.
Day(s) and
on
Switching on for...
off
Switching off for...
Time(s)
max. 65535 Secound = 18.2h
off
Switching off
on
Switching on
rs
Restore state
after (s)
Switch on
(max. 65535 s = 18.2h)
Operating distance of the relays with simultaneous switching:
 (0-255) milliseconds.
stop
Temperature less
Temperature greater
measured:
Hold<br>On
Symbol


Wake on LAN
After switching on the relay/socket when 'Send WOL' selected
and the latency (delay) gets the network receiver with the MAC (MAC - receiver)
<a href="http://en.wikipedia.org/wiki/Wake_On_LAN" target="_blank"><u>WOL - Wake on LAN</u></a> start signal.
In the network receiver 'Wake on LAN' must be enabled.
No.
Name
Send<br>WOL
MAC - receiver
delayed<br>(1-255 sec.)
Send WOL<br>immediately


Timer
Calculated sunrise & sunset<br>+ Correction max.±120 min.
= Switching time<br>&nbsp;&nbsp;999 skips switching time
on
weekday
from
to
 Relay No.:
Outlet:
Random timer
Sundial
Time
at time entry 99:99<br>- skip switching time
Interval
there
off - or
on
Su.
Mo.
Tu.
We.
Th.
Fr.
Sa.
Exceptions (day/month).
When days chosen all timers are skipped.
Jan.
Feb.
Mar.
Apr.
May
Jun.
Jul.
Aug.
Sep.
Oct.
Nov.
Dec.
Day
Direct entry
Use

Keepalive Timer 
Sends a ping [all (min)] and [if no response (no echo x)] occurs at the IP consecutive times
- The relay for starting (and / or) sends an email ('E-mail' / 'relay switch off' can be selected) [switch off for (sec.)].
After [after (min) continue] pinging continues. The IP can be pinged and tested with the "Ping" button.
'Shutdown for' = 0: there is only turned off.
'Continue after (min)' = 0: the overflow, the function does not continue. Max. Response time = 1000ms.
Send to the IP or Host
a ping
every (minute)
and if<br>no echo x
switch off<br>for (sec.)
continue<br>after (min)
detailed log
Send e-mail
Switch off relay
Save & Restart
Ping
Test
1-15 minutes
1-255 sec<br>0=only off
1-255 min<br>0=stop
x no echo, total
time of next ping
Ping - Test successful
Ping - Test unsuccessful
Echo received, 




Save configuration.
Configuration download. May be used to configure several devices.
The configuration file is saved under the name 'net-pwrctrl.cfg'.
<br><span style="color:#C96">Do not change the file "manually"!</span>
It can cause that the NET-PwrCtrl will not boot.
ERROR: Restore failed <br> defective file or wrong version.
Restore Configuration.
<br><span style="color:#FF1FAA"><b>Warning! </b>At restore the existing configuration will be deleted.</span><br> 
All settings are overwritten. MAC address remain.<br>The device restarts.<br>
 File:
Send file
The stored configuration file can be used to configure multiple NET-PwrCtrl with the same setting.
It is important to ensure that all devices have the same firmware.
Because the name of the device must be changed (hostname must be unique on the network) after the change:
Please check in the router whether the hostname (eg net-control) points to the new IP.<br>Delete old entry.
Browser (all windows) close.
Start Browser and call NET-PwrCtrl with the new hostname.
If you have a problem to find device use <a href="http://www.anel-elektronik.de/english/NET-PwrCtrl_Discoverer.zip">'NET-PwrCtrl Discoverer.exe'</a>






Logbook - the last 128 events
Last event above
Socket/Relay
Event
from (IP)






Changing the settings failed!
<b style="color:#C36">Error: </b> Host name or IP address could not be saved<br>
Please <a href="netcfg.htm"><u style="color:blue">go back</u></a> and try again.




Firmware-Update
The state of relay / sockets remains.
Off firewall and virus scanner for the time of transmission.
No WiFi and no direct connection to the LAN card.
IP of NET-PwrCtrl is unimportant.
Start<b> NET loader.exe </b> then click the bottom right of the update.
After uploading the data, the browser is refreshed. The transfer usually takes up to 10 seconds.
<b style="color:#DE614E">Attention!</b>
Should uploading breakdown (power failure, interruption of the network connection), the operation can be repeated without browser access:
Start NET-loader.exe.
Press short Reset Button.
Device restarts.
The rapid flashing of the Power LED indicates the download.
After the NET-loader program has finished, look for NET-PwrCtrl in the browser.
Are you sure?
Update
<b style="color:#DE614E"> In most cases, HTML-Upload must be performed.</b>

<b style="color:#C36">Error: </b> IP address could not be saved<br>
Please <a href="ka.htm"><u style="color:blue">go back</u></a> and try again.



The new settings are saved and NET-PwrCtrl reboot.
<b style="color:#DE614E">Important:</b> If the IP has been changed?:
If Port is changing after the hostname needs to be specified ':' and port number eg http://net-control:12345.


HTML Upload
The HTML pages can be changed and uploaded.
Please note:
There are max.<b> 256kB </b>flash memory for HTML.
File name can not be longer than 20 characters (incl. extension).
<b>Important!</b> If NET-PwrCtrl after uploading not be accessible (bug in the HTML data), direct connection can be established via <a href="/html_upload" target="_blank">/html_upload</a> to upload.
The HTML data (HTML/webpages) can be assembled with the "HTTP Image builder.exe" to a .bin file (HTML_Img.bin).
This bin file can be uploaded below. Depending on the size of the bin file the process takes up to 30 seconds.
HTML Image (HTML_Img.bin) Upload
If you are having problems with the display:<br>clear browsing data (Ctrl + Shift + Del).
Incorrect Time Format
Hours: 0 to 23 or 99
Min: 0 to 59 or 99







HELP
The help is side oriented.
Underlined
terms can be clicked.
Help window can be moved while holding the mouse button or shut down by click.

&nbsp;&nbsp;or&nbsp; <a href="http://anel-elektronik.de/ba_6.zip" style="color:#00a">Download</a><br>
Characteristics:
Relays
Input/Output
Nominal Voltage
Power consumption max.:
Max. load of relay
Tested with browsers:
Sockets
Max. load
all total max.: &nbsp;
each socket max.: &nbsp;
Dimensions
<a href="http://www.anel-elektronik.de/deutsch/Beschreibung_ADV_V6.1.pdf" target="_blank" style="color:#00a">&nbsp; User manual - PDF</a>
<a href="http://www.anel-elektronik.de/deutsch/Beschreibung_HUT_V6.1.pdf" target="_blank" style="color:#00a">&nbsp; User manual - PDF</a>
<a href="http://www.anel-elektronik.de/deutsch/Beschreibung_IO_V6.1.pdf" target="_blank" style="color:#00a">&nbsp; User manual - PDF</a>
<a href="http://www.anel-elektronik.de/deutsch/Beschreibung_HUT_ONE_V6.1.pdf" target="_blank" style="color:#00a">&nbsp; User manual - PDF</a>







Electrical measurements
Ongoing Electric measurement
Voltage
Current
Frequency
Active Power
Apparent Power
Reactive Power
Power Factor

Consumption
Intermediate meter 1
Intermediate meter 2
Electric meter
not erasable
deleted on:
Stop
Erasure
Events
Calibration
Report&nbsp;
As long as this page is opened in the browser,
electrical data are collected that can be imported as a CSV file.
Data collection starts 1 minute before opening the page.
Run
Stop
Export to CSV file
since
captured
records <br> period =
day(s) and
Start

sec. ago =<br>
day(s) &<br>





Events
Event
under<br>Voltage
Voltage<br>Surge		
Over<br>Current		
Over<br>Power		
Over<br>Frequency		
Under<br>Frequency
All in the line:
Enable
Limit
Hold
Measuring Interval =<br>2^Accumulation Interval<br>* 1/Mains Frequency =
Hold Time (sec.) =<br>Measuring interval * Hold
Test
Clear
change
Set
Reset
Saves the changes permanent.
Permanent Save
All data will be
IRRETRIEVABLY overwritten.
Are you sure?
















Setting & Calibration
<b> Warning! </b> Change, particularly the parameter marked in red,
without appropriate calibration equipment leads to loss of measurement accuracy or measurement capability.
The "Calibrate" button <b>must not be clicked</b> without reference values.
Change
Calibrate
Calculate Phase Comp.
Phase Compensation set "0" (Change) and calculate.
1. Temperature
Ambient temperature
2. Mains frequency
<b>Save in the Flash</b>
"Save in the Flash" will save the changes <b>permanently</b>.<br><b>Before </b>
changes can be discarded by a restart or turn off the device.
Measuring interval=1/frequency*2^Accumulation Interval =
Save
Mains frequency
Gain mains frequency 












Sensors
Sensor 1
Temperature
Humidity
Brightness
The measurement interval is 16 seconds.
Measurement valid

Sensor
Parameter
Value
Switch when
Relays
On/Off
Switch on Sensor 1.
Hysteresis
20 seconds after the (new)start of device or the sensor is switched on, the LED 'Measurement valid' lights up green. From this moment the relays can be switched.
By '+/-' is meant hysteresis. In the upper area, these parameters are added up, subtracted in the lower area. 22.0 +/- 0.5 = 21.5 (off); 22.5 (on).
Larger hysteresis = more fluctuations but slow switching. It also avoids repeated switching (flickering) at the switching threshold.